Main types of connections in implant dentistry. External hexagon, internal hexagon, and morse cone: A literature review

Authors

DOI:

https://doi.org/10.52076/eacad-v5i3.551

Keywords:

Internal hexagon; Implant; Dental procedures; Morse cone; External hexagon.

Abstract

Oral rehabilitation consists of a set of procedures and treatments aimed at not only aesthetics but also the functionality of the smile, ensuring the presence of healthy elements that promote a better quality of life for the patient. In this context, implant dentistry plays a fundamental role, providing aesthetics, phonetics, and quality of life when rehabilitating patients. This work seeks to understand the main differences between types of dental implants: internal hexagon, external hexagon, and Morse cone. Additionally, it aims to classify treatment types and determine the distinctions between these implants. To achieve this, a quantitative study was conducted through a narrative literature review of articles published in Brazil between 2013 and the present date. It is believed that this work can significantly contribute to the clinical practice of dental professionals, providing valuable insights into the topics discussed and assisting in making more informed clinical decisions.

References

Alghazali, N.; Burniside, G.; Moles, D. R.; Smith, P. W.; & Huynh-Ba, G. (2019). In vitro evaluation of the marginal adaptation of three different prosthetic systems to internal hexagon dental implants. Clinical Implant Dentistry and Related Research, 21(4), 697–704, 2019.

Alaghemand, H.; Mirzae, M. M.; Elhamahmadi, A.; & Saidi, A. (2013). Pré-tratamento pós-espaço da dentina radicular. Dental Research Journal, 10(4), jul. 2013.

Amorim, A. V. Do; Comunian, C. R.; Ferreira Neto, M. D’almeida; & Cruz, E. F. da. (2019). Implantodontia: histórico, evolução e atualidades. Id on Line Revista Multidisciplinar e de Psicologia, 13(45), 36-48, 2019. ISSN 1981-1179.

Alves, R. T.; et al. (2014). Enxertos ósseos autógenos intrabucais em implantodontia: estudo retrospectivo. Revista de Cirurgia e Traumatologia Buco-maxilo-facial, 14(4), 09-16, 2014.

Araújo, J. A.; & Leão, F. T. R. (2018). Restauração de dente tratado endodonticamente com pino de fibra de vidro e cerâmica odontológica: relato de caso. 2018. Trabalho de Conclusão de Curso (Dissertação) – Universidade de Uberaba, Uberaba, Minas Gerais.

Assunção, W. G.; Filho, H. G.; Zaniquelhi, O.; Tenório, D. H.; Lopes, A. R.; & Santos, P. H. (2016). Micro-gap and bacterial leakage in implants with Morse taper. Dental Press Implantology, 10(2), 32-37, 2016.

Bacchi, A.; Caldas, R. A.; Schmidt, D.; Detoni, M.; Souza, M. A.; Cecchin, D.; & Farina, A. P. (2019). Resistência à fratura e distribuição de tensão em pré-molares restaurados com pinos e núcleos fundidos ou pinos de fibra de vidro, considerando a influência da férula. BioMed Research International, v. 2019, Artigo ID 2196519, 7 páginas.

Barbosa, E. A. S. L. et al. (2023). Implante cone morse x hexágono externo, vantagens e desvantagens no aspecto clínico. Revista Interface-Integrando Fonoaudiologia e Odontologia, 4(1), 5-14, 2023.

Campos, F. A. L.; & Melo, A. R. (2019). Próteses sobre implantes cone morse cimentadas versus parafusadas: vantagens e desvantagens. Brazilian Journal of Implantology and Health Sciences, 1(4), 84-100, 2019. Disponível em: https://bjihs.emnuvens.com.br/bjihs/article/view/13. Acesso em: 8 abr. 2024.

Carvalho, D. C.; & Marques, D. M. (2019). Pinos de fibra de vidro na reabilitação funcional e estética: relato de caso clínico. Ciência & Saúde, São Luís, 21(2).

Cieluck, D. C. (2011). Reabilitação oral complexa - Associação de PPR com encaixes intra-coronários: relato de caso clínico. Trabalho de Conclusão de Curso (dissertação). Faculdade de Odontologia, Universidade Federal de Pelotas, Pelotas, RS, 2011.

Costa, C. R. R. (2017). As diferentes características de sistemas e modelos de implantes dentários: uma revisão de literatura. Semana Acadêmica: Revista Científica, 1(108), 1-8, 2017. https://semanaacademica.org.br/system/files/artigos/as_diferentes_caracteristicas_de_sistemas_e_modelos_de_implantes_dentarios.pdf.

Fabris, R. R.; Caldas, R. A.; Miranda, M. E.; Borba, P.; Olivieri, K. A. N.; Brandt, W. C., et al. (2021). Comparative stress evaluation of different types of prosthetic abutment and crown with an internal connection implant. Research, Society and Development, 10(4), 1-16.

França, S. S. M.; & Paraguassu, E. C. (2022). Carga imediata em prótese total implantosuportada: revisão de literatura. Brazilian Journal of Implantology and Health Sciences, 4(1), 14-34, 2022.

Ferreira, F. I. (2017). Visão contemporânea do sistema cone-morse em reabilitações protéticas: revisão crítica de literatura. 2017. 27 f. Trabalho de Conclusão de Curso (Bacharelado em Odontologia) - Universidade Federal do Rio Grande do Sul, Porto Alegre, 2017. <https://www.lume.ufrgs.br/bitstream/handle/10183/170340/001050799.pdf.

Gonçalves, A. P. R.; Ogliari, A. O.; Jardim, P. S.; & Moraes, R. R. (2013). Agentes de limpeza química e ligação a postes de fibra de vidro. Faculdade de Odontologia, Universidade Federal de Pelotas, Pelotas, RS. Braz Oral Res., São Paulo, 27(1), 70-72, jan./fev. 2013.

Johnson, E.; White, F. et al. (2018). Sistema Cone Morse: benefícios e desafios. Jornal de Reabilitação Oral, 18(2), 67-75, 2018.

Fernandes, R. C. J. et al. (2014). Implantodontia: próteses totais fixas sobre implante com carga imediata em mandíbula. Revista de Iniciação Científica da Universidade Vale do Rio Verde, 4(1), 2014.

Kalil, E. C.; Santos, E. M.; Dottore, A. M.; Sobral, S. S.; Sobral, A. P. T.; Fernandes, K. P. S. et al. (2021). Prospective radiographic evaluation of peri-implant bone maintenance on osseointegrated implants with frictional morse taper connection and platform switching: cases report. Research, Society and Development, 10(2), 1-8, 2021.

Lee, D. W.; Choi, Y. S.; Park, K. H.; Kim, C. S.; Moon, I. S.; & Bae, H. E. (2015). Comparative study on bacterial microleakage at the implant-abutment interface: relatively microgap-free external hexagon compared with conventional external hexagon. The Journal of Advanced Prosthodontics, 7(2), 131-137, 2015.

Lima, K. G. A.; & Laurindo, B. M. (2019). Reabilitação estética anterior através de coroas metalocerâmicas: relato de caso. Scire Salutis, 9(3), 16-21, 2019. DOI: http://doi.org/10.6008/CBPC2236-9600.2019.003.0003.

Lopes Dos Reis, G.; Santos, R. W. P.; Silva Pereira, T.; & Cury Viana, H. (2023). Sistema Cone Morse: indicações, vantagens e estudo comparativo: uma revisão narrativa de literatura. Scientia Generalis, 4(2), 377-387, 2023. DOI: 10.22289/sgV4N2A32. <https://scientiageneralis.com.br/index.php/SG/article/view/526.

Luppino, M. (2020). Impacto da adaptação componente protético/implantes na saúde periimplantar. 2020. Repositório da Faculdade Sete Lagoas – FACSETE

Misch, C. E. (2019). Contemporary Implant Dentistry. (4. ed.). Elsevier.

Nayak, R. (2018). Internal Hex Implants: A Literature Review. Journal of Interdisciplinary Dentistry, 8(3), 109-113, 2018.

Oliveira, D. de; & Silva, E. B. de S. (2018). O impacto da reabilitação oral na qualidade de vida do paciente desdentado parcial. UNIT.SE. Centro, Aracaju – SE, 2018.

Oliveira, M. A. S.; Medeiros, F. C.; de Almeida, E. O.; Franscischone, C. E.; & Santiago Júnior, J. F. (2020). Morse Taper Connection Implants versus External Hexagon Connection Implants: A Systematic Review and Meta-Analysis. The International Journal of Oral & Maxillofacial Implants, 35(5), 984-994, 2020.

Pereira, A. S. et al. (2018). Metodologia da pesquisa científica. [e-book]. Santa Maria/RS: Ed. UAB/NTE/UFSM, 2018. <https://www.ufsm.br/app/uploads/sites/358/2019/02/Metodologia-da-Pesquisa-Cientifica_final.pdf>.

Piao, C. M.; Kim, H. S.; Kim, S. M.; & Seol, Y. J. (2019). Influence of implant-abutment connection designs on peri-implant bone levels: a systematic review and meta-analysis. Journal of Prosthodontic Research, 63(4), 373-383, 2019.

Rocha Tunes, U. (2017). Implantodontia. Journal of Dentistry & Public Health (inactive/archive only), v. 8, 2017.

Rocha, A. de O.; Lima, T. O.; Anjos, L. M. dos; Sá Santos, L. F.; Anjos Santos, R. de M.; Silva Filho, W. J.; Macedo, C. V. de S.; Lima dos Santos, M. A.; Andrade, R. M.; & Meneses Junior, N. S. (2021). Uso de pino de fibra de vidro para reabilitar unidade dental comprometida por extensa lesão cariosa: relato de caso. Revista Eletrônica Acervo Saúde | ISSN 2178-2091, 13(6), Rio de Janeiro, 2021.

Silva, R. C. da. (2016). Reabilitação protética em canais amplamente destruídos utilizando retentores intrarradiculares: uma revisão de literatura. Dissertação (Mestrado) - Faculdade de Macapá, Macapá, 2016.

Silva, F. L.; Rodrigues, F.; Pamato, S.; & Pereira, J. R. (2012). Tratamento de superfície em implantes dentários: uma revisão de literatura. Revista da Faculdade de Odontologia - UPF [online], Passo Fundo, 21(1), 136-142, jan./abr. 2016. ISSN 1413-4012.

Silva, C.; Santos, D. et al. (2019). Implantes dentários com plataforma switching: uma revisão sistemática. Revista Brasileira de Odontologia, 30(4), 213-220, 2019.

Silveira, A. P.; & Sousa, L. F. (2019). Resolução estética com a utilização de pino de fibra de vidro e resina composta: estudo de caso. Trabalho de Conclusão de Curso. Universidade do Extremo Sul Catarinense – UNESC. Santa Catarina, 2019.

Smith, A.; Jones, B. et al. (2015). Implantes Dentários: Uma revisão abrangente. Revista de Implantes Dentários, 25(3), 123-135, 2015.

Sousa, A. S.; Oliveira, G. S.; & Alves, L. H. (2021). A pesquisa bibliográfica: princípios e fundamentos. Cadernos da Fucamp, 20(43), 2021. https://revistas.fucamp.edu.br/index.php/cadernos/article/view/2336.

Souza, G. A. et al. (2016). Plataformas em implantes dentais: um paralelo entre implantes de hexágono interno, hexágono externo e cone-morse. Ciência Atual – Revista Científica Multidisciplinar do Centro Universitário São José, 7(1), 2-14, 2016.

Shakir, D. A. M.; & Hassan, S. H. (2019). Morse Taper Implants: A Comprehensive Review. Journal of Oral Implantology, 45(6), 477-483, 2019.

Sukumar, S.; Giri, V.; Mahadevappa, P.; & Jayade, B. (2017). Prospective Clinical Study on the Survival Rate of Internal Hexagon Implants Placed at Various Levels of Residual Bone. Journal of International Society of Preventive & Community Dentistry, 7(supl.3), S148-S152, 2017.

Varise, C. G.; Abi-Rached, F. O.; Messias, A. M.; das Neves, F. D.; Segalla, J. C. M.; & Reis, J. M. D. S. N. (2016). Sistema Cone Morse e utilização de pilares com plataforma switching. Revista Brasileira de Odontologia, 72(1/2), 56, 2016.

Published

19/11/2024

How to Cite

Wentz, M. R., Nascimento, N. A. da S. ., & Montesino, A. C. . (2024). Main types of connections in implant dentistry. External hexagon, internal hexagon, and morse cone: A literature review. E-Acadêmica, 5(3), e2053551. https://doi.org/10.52076/eacad-v5i3.551

Issue

Section

Health and Biological Sciences